Bulletin of JSME · 1969 · 39 citations · 0 references
EngineeringCivil EngineeringWater Resources ManagementFluid DynamicsHydraulic EngineeringHydraulicsFlow ResistancePipe FlowDimensionless NumbersDimensionless QuantitiesExperimental Results InterpretationFlow Distribution AnalysisFlow Rate CharacteristicsFlow Rate EstimationPipesPressure Recovery
Formulas for calculating the flow rate ratio of each branch pipe are derived taking the diffuser effect on divided flow and the nozzle effect on confluent flow which is caused by branching streams in a header into consideration. Effects of the divided flow factor σD and of the confluent flow factor σo in those formulas on the flow rate ratio of each branch pipe are evaluated from the experimental results for water. The factors σD and σo are dimensionless numbers given by [numerical formula] where ησ is the diffuser factor which represents the pressure recovery factor due to branching of the fluid from a header, ψn is the nozzle factor due to adding of the fluid from branch pipes into a header, (ζ+λι/d) and m are the resistance coefficient of branch pipe and the ratio of crosssectional area of the header to one of the branch pipe respectively. A method for calculating the flow rate ratio of each branch pipe in the case where the inlet or the outlet of header is placed between both closed ends of the header is also presented.