Review of Scientific Instruments · 2007 · 18 citations · 5 references
EngineeringElectrical EngineeringNuclear EngineeringAnalog ElectronicsPlasma PhysicsSensorsAnalog Integrated CircuitsAnalog IntegrationDifferential AmplifiersMagnetic SensorsMagnetized PlasmaPlasma DiagnosticsInductive Magnetic SensorsInductive SensorsIntegrated Magnetic SensorsMagnetic DiagnosticsMagnetic Field MeasurementsMagnetometer Drift CorrectionMagnetometer InstrumentationTokamak Equilibrium
An analog integrator, which automatically compensates an integrating drift, has been developed for the magnetic diagnostics in the Korea superconducting tokamak advanced research (KSTAR). The compensation of the drift is done by the analog to digital converter-register-digital to analog converter in the integrator. The integrator will be used in the equilibrium magnetic field measurements by using inductive magnetic sensors during a plasma discharge in the KSTAR machine. Two differential amplifiers are added to the signal path between each magnetic sensor and the integrator in order to improve the performance of the integrator because a long signal cable of 100 m will be used for the measurement in the KSTAR machine. In this work, the characteristics of the integrator with two differential amplifiers are experimentally investigated.