Medicine & Science in Sports & Exercise · 2015 · 198 citations · 34 references
EducationPhysiologyExercise PhysiologyExercise TestingMetabolic PhysiologyAerobic ExerciseCardiopulmonary Exercise TestingCardiorespiratory FitnessCycle Ergometer TestingMetabolic Responses To ExercisePhysical FitnessBlood Lactate AssessmentBlood Lactate MeasurementBlood Lactate TestingMaximal Lactate Steady StateMaximal Oxygen Uptake TestingPower OutputRamp Test ProtocolRespiratory Compensation
UNLABELLED: Critical power (CP), respiratory compensation point (RCP), maximal lactate steady state (MLSS), and deoxyhemoglobin breakpoint ([HHb]BP) are alternative functional indices that are thought to demarcate the highest exercise intensity that can be tolerated for long durations. PURPOSE: We tested the hypothesis that CP, RCP, MLSS, and [HHb]BP occur at the same metabolic intensity by examining the pulmonary oxygen uptake (V˙)O2p and power output (PO) associated with each "threshold." METHODS: Twelve healthy men (mean ± SD age, 27 ± 3 yr) performed the following tests on a cycle ergometer: i) four to five exhaustive tests for determination of CP, ii) two to three 30-min constant-power trials for MLSS determination, and iii) a ramp incremental exercise test from which the V˙O2p and PO at RCP and [HHb]BP were determined. During each trial, breath-by-breath V˙O2p and ventilatory variables were measured with a metabolic cart and flowmeter turbine; near-infrared spectroscopy-derived [HHb] was monitored using a frequency domain multidistance system, and arterialized capillary blood lactate was sampled at regular intervals. RESULTS: There were no differences (P > 0.05) among the V˙O2p values associated with CP, RCP, MLSS, and [HHb]BP (CP, 3.29 ± 0.48; RCP, 3.34 ± 0.45; MLSS, 3.27 ± 0.44; [HHb]BP, 3.41 ± 0.46 L·min(-1)); however, the PO associated with RCP (262 ± 48 W) and [HHb]BP (273 ± 41 W) were greater (P < 0.05) than both CP (226 ± 45 W) and MLSS (223 ± 39 W), which, themselves, were not different (P > 0.05). CONCLUSIONS: Although the standard methods for determination of CP, RCP, MLSS, and [HHb]BP are different, these indices occur at the same V˙O2p, suggesting that i) they may manifest as a result of similar physiological phenomenon and ii) each provides a valid delineation between tolerable and intolerable constant-power exercise.
34
Metabolic and respiratory profile of the upper limit for prolonged exercise in man
David C. Poole, Susan A. Ward, Gerald W. Gardner et al. · Ergonomics · 1988 · 777 citations
Andrew M. Jones, Daryl P. Wilkerson, Fred J. DiMenna et al. · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · 2007 · 469 citations
Romain Meeusen, Martine Duclos, Carl Foster et al. · European Journal of Sport Science · 2012 · 399 citations · Full text