Publication | Closed Access
Reconstruction of massive rotator cuff lesions with a synthetic interposition graft: a prospective study of 41 patients
166
Citations
25
References
2005
Year
Abstract In the present prospective study, we report about our experience with massive rotator cuff tears treated by means of a nonresorbable transosseously fixated patch combined with subacromial decompression. Forty‐one patients were followed clinically and radiographically for a mean duration of 43 months. Their mean preoperative Constant and Murley score improved ( P <0.001) from 25.7 preoperatively to 72.1 postoperatively. Substantial pain relief and improvement in the performance of activities of daily living were obtained. Anatomically, the repair resulted in a mean acromiohumeral interval of 8.6 mm. At the latest follow‐up, three patients presented with a new tear between the inserted mesh and the supraspinatus musculotendinous unit. Reoperations were not performed. For short‐term periods, restoring a massive rotator cuff tendon defect with synthetic grafts combined with subacromial decompression can give significant pain relief and improvement of range of motion and strength with few complications.
| Year | Citations | |
|---|---|---|
Page 1
Page 1