Implant Dentistry · 2006 · 33 citations · 25 references
DentistryDental Biomaterials ScienceImplant DentistryDental MaterialsImplant SurgeryMechanical Properties Of Dental MaterialsBone MechanicsFracture BiomechanicsImplant BiomechanicsImplant MaterialsPeri-implant Bone Level AssessmentPeri-implant Tissue HealthBirefringence AnalysisBone-implant Contact AssessmentBone-to-implant ContactCollagen Fiber StructureCollagen OrientationDental ImplantsFiber OrientationFractography
PURPOSE: Fracture of an implant is one of the possible complications of dental implants. It is a quite rare event but of high clinical relevance. Nevertheless, it represents an important opportunity for evaluating the peri-implant bone-tissue response to implant overloading in human beings. The aim of the present study was a scanning electron microscopy evaluation of a screw-shaped implant retrieved because of fracture and a birefringence analysis of the tissue near the fractured implant. MATERIALS AND METHODS: There was 1 fractured screw-shaped implant retrieved from a patient with a trephine bur, and it was processed for histology. The specimen was analyzed under both scanning electron microscopy and circularly polarized light microscopy. RESULTS: The scanning electron microscopy fractography analysis showed the typical signs of a fatigue-fracture, with large plastic deformations on the implant. The fracture seemed to start from the internal coil of the implant. Under circularly polarized light microscopy investigation, a bone-implant contact percentage of 81.6% +/- 1.5% (mean +/- standard deviation) was found. The amount of the transverse collagen fibers was of 68.3%, and the amount of the longitudinal collagen fibers was of 31.7%. The difference was statistically significant for z = 2.247 (P = 0.025). CONCLUSION: The fracture of the implant was most probably correlated to a fatigue of the material mainly associated to a lesion of the internal coil. The high level of bone-implant contact percentage was correlated to a predominant transverse collagen fiber orientation of the collagen fibers in the peri-implant bone.
25
Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws.
R Adell, Bengt O. Eriksson, Ulf Lekholm et al. · PubMed · 1990 · 1.9K citations
Forces and moments on Branemark implants.
Bo Rangert, Torsten Jemt, L Jörnéus · PubMed · 1989 · 624 citations
Bending overload and implant fracture: a retrospective clinical analysis.
Bo Rangert, P H Krogh, Burton Langer et al. · PubMed · 1995 · 553 citations
Dynamic response of bone and muscle tissue.
James H. McElhaney · Journal of Applied Physiology · 1966 · 501 citations
Medicine, Anatomy, Physiology +14