Architectural Science Review · 1996 · 52 citations · 6 references
ArchitectureBuilding ScienceMeteorologyBuilding Performance SimulationClimatologyWeather ForecastingBuilding Energy ModelingBuilding Energy PerformanceBuilding Energy SystemsEnergy SimulationEnergy UseBuilding Energy Consumption AnalysisBuilding Energy DemandBuilding Energy Performance SimulationElectricity Consumption ForecastingEnergy System SimulationEnergy Use PredictionMeteorological Data AnalysisWeather Data Analysis
Measured hourly weather data for the 16-year period from 1979 to 1994 were analysed. Statistics techniques were used to develop a typical meteorological year (TMY) for building energy simulation. We used the Finkelstein-Schafer (FS) and the Kolmogrov-Smirnov (KS) two-sample statistics to analyse and select representative weather data for the formulation of a TMY for Hong Kong. Building energy computer simulations using DOE-2 were carried out. It was found that the monthly electricity consumption profile from the TMY was close to that from the 16-year long-term weather data. The root-mean-square error was 27.7MWb, 3.9% of the long-term mean monthly consumption. On an annual basis, TMY predicted 1.5% more consumption than the long-term.
6
Practical Nonparametric Statistics
David J. Groggel, W. J. Conover · Technometrics · 2000 · 11.1K citations
Improved goodness-of-fit tests
J. M. Finkelstein, Ray E. Schafer · Biometrika · 1971 · 308 citations
The generation of a “typical meteorological year” for the city of Athens
D. K. Pissimanis, Greg Karras, V. A. Notaridou et al. · Solar Energy · 1988 · 112 citations