Radiology · 2010 · 19 citations · 16 references
MedicineOncologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingPerfusion ImagingTissue Perfusion AssessmentTumor CharacterizationTumor ImagingBlood Volume AssessmentBlood Volume EstimationMagnetic ResonanceNuclear Magnetic Resonance RelaxometryTransverse RelaxationTransverse Relaxation TimeTumor NeovascularizationTumor Perfusion Imaging
PURPOSE: To evaluate a susceptibility-corrected multiecho magnetic resonance (MR) relaxometry technique for an accurate and robust determination of DeltaR2* as a noninvasive surrogate parameter of the perfused tumor blood volume. MATERIALS AND METHODS: All experiments were approved by the institutional animal care committee. In a glass tube phantom with different superparamagnetic iron oxide (SPIO) particle concentrations and at tumor mice xenografts with DU-4475, HT-1080, and MDA-MB-435 tumors (n = 15 total, n = 5 per model) with different degrees of neovascularization after injection of different ultrasmall SPIO (USPIO) doses changes of the transverse relaxation rate (DeltaR2*) were determined by using a fixed echo time (TE) of 22 msec and a susceptibility-corrected multigradient-echo technique. The mean DeltaR2* value and the vascular volume fraction (VVF) of each tumor was determined and compared with independent in vivo fluorescent tumor perfusion measurements and histologic analysis helped determine microvessel density (MVD). Statistical differences were tested by using analysis of variance and linear correlations. RESULTS: For the phantom study, DeltaR2* maps calculated with a fixed TE of 22 msec showed a higher standard deviation of the noise index compared with the susceptibility-corrected multiecho technique. For the xenograft model, mean tumor DeltaR2* values (+/- standard error of the mean) showed significant differences between the various tumors (eg, DU-4475: 12.3 sec(-1) +/- 2.67, HT-1080: 36.47 sec(-1) +/- 5.84, and MDA-MB-435: 64.01 sec(-1) +/- 8.87 at 80 mumol of iron per kilogram; P < .05). DeltaR2* values increased dose dependently and in a linear fashion, resulting in reproducibly stable VVF measurements. Fluorescent tumor perfusion measurements and MVD counts corroborated the MR results. CONCLUSION: Susceptibility-corrected multiecho MR relaxometry allows a highly accurate and robust determination of DeltaR2* and VVF with an excellent dynamic range for tumor characterization at clinically relevant doses of USPIO.
16
Perfusion imaging with NMR contrast agents
Bruce R. Rosen, John W. Belliveau, James M. Vevea et al. · Magnetic Resonance in Medicine · 1990 · 1.2K citations
Medicine, Physiology, Radiology +17
Ir�ne Tropr�s, Stéphan Grimault, Albert Vaeth et al. · Magnetic Resonance in Medicine · 2001 · 337 citations · Full text
Medicine, Neuroscience, Radiology +17
Eric P. Winer, Julie R. Gralow, Lisa Diller et al. · Journal of Clinical Oncology · 2008 · 290 citations · Full text
Medicine, Cancer Biology, Oncology +11