Abstract

Four methods of calculating left ventricular ejection fraction from equilibrium radionuclide angiography have been assessed for inter-observer variability and compared to single-plane contrast cineangiography. The superiority of data-processing methods which use a left ventricular region of interest which follows the changing size of the left ventricle into systole is demonstrated. A simple method of correcting for background is suggested as an alternative for those centres not possessing the necessary software for methods involving a changing region of interest.