MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedicsPain ManagementSpine SurgeryLumbar Spine SurgeryMinimally Invasive Spine SurgeryPain AssessmentPain MeasurementPain OutcomesSpinal FusionLower Extremity PainLumbar Spinal FusionMinimally Invasive Lumbar FusionMinimally Invasive Sacroiliac Joint FusionOperative TechniqueOutcomes After Spinal FusionPain ScoresSacroiliac Joint Implantation
BACKGROUND: Sacroiliac joint (SI) pain is an often-overlooked cause of lower-back pain, due in part to a lack of specific findings on radiographs and a symptom profile similar to other back-related disorders. A minimally invasive surgical (MIS) approach to SI joint fusion using a series of triangular, titanium plasma spray-coated implants has shown favorable outcomes in patients with SI joint pain refractory to conservative care. The aim of this study was to provide a multicenter experience of MIS SI joint fusion using a patient-level analysis. PATIENTS AND METHODS: We report a patient-level analysis from 144 patients with a mean of 16 months postoperative follow-up. Demographic information, perioperative measures, complications, and clinical outcomes using a visual analog scale for pain were collected prospectively. Random-effects regression models were used to account for intersite variability. RESULTS: The mean age was 58 years, 71% of patients were female, and 62% had a history of lumbar spinal fusion. Mean (95% confidence interval [CI]) operative time was 73 minutes (25.4-118), blood loss was minimal, and hospital stay was 0.8 days (0.1-1.5). At follow-up, mean (95% CI) visual analog scale pain scores improved by 6.1 points (5.7-6.6). Substantial clinical benefit, defined as a decrease in pain by >2.5 points or a score of 3.5 or less, was achieved in 91.9% of patients (95% CI 83.9%-96.1%), and 96% (95% CI 86.3%-98.8%) of patients indicated they would have the same surgery again. CONCLUSION: When conservative measures fail to relieve symptoms resulting from degeneration or disruption of the SI joint, MIS SI joint fusion using a series of triangular, porous, titanium plasma spray-coated implants is a safe and effective treatment option.
29
Theo Vos, Abraham D Flaxman, Mohsen Naghavi et al. · The Lancet · 2012 · 8.4K citations · Full text
Anne G. Copay, Steven D. Glassman, Brian R. Subach et al. · The Spine Journal · 2008 · 1.2K citations
The Sacroiliac Joint in Chronic Low Back Pain
Anthony C. Schwarzer, Charles N. Aprill, Nikolai Bogduk · Spine · 1995 · 981 citations