American Journal of Roentgenology · 2002 · 25 citations · 21 references
MedicineRadiologySurgeryDiagnostic ImagingDiagnostic RadiologyInterventional RadiologyCardiovascular ImagingIntravascular ImagingMagnetic Resonance ImagingRenal ImagingVascular ImagingAnimal Model EvaluationAnimal Model ImagingContrast-enhanced Magnetic Resonance AngiographyMagnetic Resonance AngiographyRenal Artery ImagingRenal Artery Stenosis DetectionRenal Artery Stenosis ImagingWilcoxon Signed-rank Test
OBJECTIVE: Catheter-based intraarterial injections of gadolinium are useful during MR imaging-guided endovascular procedures to generate rapid vascular road maps. Using an animal model of renal artery stenosis, we tested the hypothesis that intraarterial gadolinium-enhanced MR angiography is as accurate as IV gadolinium-enhanced MR angiography and digital subtraction angiography (DSA). We also tested the hypothesis that intraarterial MR angiography uses less gadolinium than IV MR angiography. MATERIALS AND METHODS: We induced bilateral renal artery stenosis in five pigs. All pigs underwent comparative imaging with DSA, IV MR angiography, and aortic catheter-directed intraarterial MR angiography. For IV and intraarterial MR angiography, we used the same three-dimensional acquisition. We assessed differences in quantitative stenosis measurements among DSA, IV MR angiography, and intraarterial MR angiography using the Wilcoxon's signed rank test. RESULTS: Mean stenosis measurements (+/-SD) were as follows: DSA, 58% +/- 12%; IV MR angiography, 63% +/- 9.3%; and intraarterial MR angiography, 64% +/- 11%. There were no statistically significant differences in accuracy between DSA and IV MR angiography (p = 0.06), DSA and intraarterial MR angiography (p = 0.16), or IV and intraarterial MR angiography (p = 0.70). Intraarterial MR angiography used a mean gadolinium dose of 5.6 mL, compared with 9 mL for IV MR angiography. CONCLUSION: In swine, IV and intraarterial MR angiography have a similar accuracy for detecting renal artery stenosis. Intraarterial MR angiography uses smaller doses of injected gadolinium.
21
Measuring carotid stenosis. Time for a reappraisal.
Andrei V. Alexandrov, Christopher F. Bladin, Robert Maggisano et al. · Stroke · 1993 · 196 citations
Xian Mang Pan, David Saloner, Linda M. Reilly et al. · Journal of Vascular Surgery · 1995 · 143 citations · Full text
Medicine, Surgery, Ultrasonography +14
Azotemia: gadopentetate dimeglumine as contrast agent at digital subtraction angiography.
W. Jean Matchett, David R. McFarland, Donna Russell et al. · Radiology · 1996 · 138 citations
Medicine, Cardiology, Radiology +16