A comparative study of corrosion inhibition efficiency of stem and leaves extract of Ocimum sanctum (Holy Basil) for mild steel in HCl solution

Nutan Kumpawat, Alok Chaturvedi, Rajesh Kumar Upadhyay

Protection of Metals and Physical Chemistry of Surfaces · 2010 · 16 citations · 7 references

Concepts

Abstract

Corrosion inhibition efficiency of Ocimum sanctum extract for mild steel in hydrochloric acid solution was studied by weight loss and thermometric methods. Inhibition efficiency increases with the increasing concentration of extract and decreases with increase in acid strength. Results of inhibition efficiency obtained by two methods have been found in good agreements with each other. Maximum inhibition efficiency was found 98.67% in 0.5 N HCl acid with 1.2% stem extract, whereas it was 96.02% in leaves extract with same concentration i.e. 1.2%.

References

7