Publication | Open Access
In vivo assessment of left atrial contractile performance in normal and pathological conditions using a time-varying elastance model.
130
Citations
32
References
1994
Year
We conclude that (1) in the intact heart, LA contraction may be approximated by time-varying elastance with time-dependent changes in E(t) and that (2) LA systolic P-V relations using either the nonisochronal maximum P-to-V ratio or end systole may be useful as an estimate of Emax, are highly linear and sensitive to calcium-induced changes in inotropic state, and may be useful in identifying LA chamber adaptation to chronic hemodynamic loads.