Journal of Bone and Mineral Research · 1992 · 38 citations · 11 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBone HealthBone Quantity AssessmentImaging AssessmentMusculoskeletal RadiographyRadiographic AssessmentRadiographic ImagingBone DensitometryBone Density EstimationBone Mass GainBone Mineral DensityBone Mineral Density AssessmentCalibration ProceduresMineral Content EstimationRadiographic Bone Measurement
Interunit variability among bone densitometers is due to different factors, including different calibration procedures and algorithms and variability in photon source energies and/or intensities. Other factors, such as the choice of scan parameters or the analysis procedures, can also introduce variability. The new generation of dual-energy x-ray absorptiometry (DXA) has partially improved this situation. The aim of this study was to investigate the operator-dependent analysis procedures that can affect scan results and to evaluate the phantom and in vivo interunit variation of some DXA instruments. Four DXA instruments (QDR 1000 and 1000/W, Hologic, Inc.) were used. Potential sources of variability in the analysis procedures of anteroposterior lumbar spine and hip scans were considered: in most cases these procedures significantly influenced scan results. On lumbar spine, an enlargement of the scan window of less than 3 cm was responsible for an average increase in bone mineral density (BMD) of about 3%. On the hip, lowering the scan window by about 1 cm accounted for an increase in the whole-segment BMD of about 4%. After standardization of analysis procedures, interunit and intraunit coefficients of variation and percentage differences among instruments were less than 1% for all the parameters considered (area and bone mineral content and density) with both an anatomic and a geometric phantom, and in nine subjects scanned by two different devices the percentage difference in BMD was greater than 2%. This study shows that present interunit variability allows comparisons among laboratories, but only if highly standardized analysis procedures are used.
11
Osteoporosis: Etiology, Diagnosis, and Management
Michael Kleerekoper · Mayo Clinic Proceedings · 1988 · 333 citations
The effect of positioning on dual energy X-ray bone densitometry of the proximal femur
Charles R. Wilson, I. Fogelman, G. M. Blake et al. · Bone and Mineral · 1991 · 59 citations
Calibration of dual-energy X-ray absorptiometry for bone density
Richard B. Mazess, J. Trempe, Joseph Bisek et al. · Journal of Bone and Mineral Research · 1991 · 58 citations