Audiology and Neurotology · 2006 · 53 citations · 17 references
Health ProfessionsAnatomyOtolaryngologyAcousticsAuditory AnatomyOtologyEar AnatomyOssicular Chain AnatomyStapes AnatomyTemporal Bone AnatomyFacial Recess AnatomyFacial Recess ApproachStapes BiomechanicsStapes MotionStapes Orientation
Methodological differences in sound-induced stapes velocity (Vs) measurements in live and cadaveric ears were examined using fresh cadaveric temporal bones. On average, differences in preparation (sectioning the stapedius tendon, removing the facial nerve, and widely opening the facial recess) had statistically insignificant effects on measured Vs. Differences in the achievable measurement angle (with respect to the axis of piston-like stapes motion) had a significant effect on measured Vs below 2 kHz. These results suggest that much if not all of the differences in Vs measurements between live and cadaveric ears can be explained by the differences in measurement angle between the two preparations. Measurement angle was found to have minimal effect on measured Vs above 2 kHz. This demonstrates that the commonly used method of estimating stapes translational velocity by dividing the measured velocity by the cosine of the measurement angle is not valid above 2 kHz.
17
Acoustic responses of the human middle ear
Susan E. Voss, John J. Rosowski, Saumil N. Merchant et al. · Hearing Research · 2000 · 210 citations
Laser Doppler vibrometer (LDV)--a new clinical tool for the otologist.
Richard L. Goode, Geoffrey R. Ball, S Nishihara et al. · PubMed · 1996 · 136 citations
Medicine, Otolaryngology, Surgery +17