Physical Review · 1964 · 30 citations · 10 references
Natural SciencesMaterials SciencePhysicsCondensed Matter PhysicsMaterials PhysicsSolid State PhysicsAcoustic MeasurementAcoustic Wave PropagationPhysical AcousticsSuperconducting MaterialsUltrasonicsUltrasound PhysicsFrequency Dependence Of AttenuationHigh-temperature SuperconductorsPhononsSound AttenuationSuperconducting GapUltrasonic AcousticsUltrasonic AttenuationUltrasonic Propagation
Phonon attenuation versus temperature measurements have been made on single-crystal niobium from 1.3 to 10\ifmmode^\circ\else\textdegree\fi{}K for longitudinal phonon frequencies of 30 and 220 Mc/sec using the echo technique. In addition, the frequency dependence of the normal attenuation at 1.42\ifmmode^\circ\else\textdegree\fi{}K has been determined from 30 Mc/sec to approximately 450 Mc/sec. Finally, time-of-flight shear and longitudinal measurements have been made at 4.2\ifmmode^\circ\else\textdegree\fi{}K and 30 Mc/sec. By averaging numerous experimental points it has been calculated that the superconducting energy gap is $(3.63\ifmmode\pm\else\textpm\fi{}0.06)k{T}_{c}$ for sound propagation along the [100], [110], and [111] crystallographic axes; that the normalized gap varies more strongly with the reduced temperature near ${T}_{c}$ than is predicted by the BCS theory; that the Debye temperature at 4.2\ifmmode^\circ\else\textdegree\fi{}K is (271\ifmmode\pm\else\textpm\fi{}5)\ifmmode^\circ\else\textdegree\fi{}K, as calculated from the computed elastic constants; and that the ratio of superconducting-to-normal attenuation falls below the value predicted by BCS as the temperature is increased towards ${T}_{c}$ for the 30-Mc/sec phonons. The attenuation varied as the square of the frequency below 110 Mc/sec, while for the higher frequencies the dependence on frequency decreased. Thus, at 220 Mc/sec, $\mathrm{ql}\ensuremath{\sim}1$. The samples were grown by an electron beam zone refining technique; and from well-oriented samples, experimental crystals were selected on the basis of mass spectrographic analyses and by measurements of ${T}_{c}$ by the ultrasonic method. A typical acceptable sample was at least 99.8% pure and had ${T}_{c}=(9.15\ifmmode\pm\else\textpm\fi{}0.02)$\ifmmode^\circ\else\textdegree\fi{}K. Other typical values were a resistivity ratio of 520\ifmmode\pm\else\textpm\fi{}50 and upper critical magnetic fields of 1710\ifmmode\pm\else\textpm\fi{}20 Oe and 2020\ifmmode\pm\else\textpm\fi{}20 Oe at 4.2 and 1.4\ifmmode^\circ\else\textdegree\fi{}K, respectively. The results are briefly discussed in terms of several models and calculations which have been reported in the literature.
10
J. Bardeen, Leon N. Cooper, J. R. Schrieffer · Physical Review · 1957 · 13K citations · Full text
Study of Superconductors by Electron Tunneling
K. Megerle · Physical Review · 1961 · 415 citations
Ultrasonic Attenuation in Superconductors
T. Tsuneto · Physical Review · 1961 · 174 citations