Radiology · 2007 · 103 citations · 13 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyRadiation DosimetryAttenuation CorrectionComputed TomographyPediatric Nuclear ImagingPhantom DosimetryPositron Emission TomographyRadiation Dose MeasurementComputed Tomography Dose IndicesComputed Tomography Phantom DosimetryComputed Tomography-based Attenuation CorrectionMedical Imaging Radiation DosePediatric Positron Emission TomographyPet Attenuation CorrectionPet-computed TomographyPhantom-based Dose Measurement
PURPOSE: To evaluate the dose from the computed tomographic (CT) portion of positron emission tomography (PET)/CT to determine minimum CT acquisition parameters that provide adequate attenuation correction. MATERIALS AND METHODS: Measurements were made with a PET/CT scanner or a PET scanner, five anthropomorphic phantoms (newborn to medium adult), and an ionization chamber. The CT dose was evaluated for acquisition parameters (10, 20, 40, 80, 160 mA; 80, 100, 120, 140 kVp; 0.5 and 0.8 second per rotation; 1.5:1 pitch). Thermoluminescent dosimetry was used to evaluate the germanium 68/gallium 68 rod sources. A phantom study was performed to evaluate CT image noise and the adequacy of PET attenuation correction as a function of CT acquisition parameters and patient size. RESULTS: The volumetric anthropomorphic CT dose index varied by two orders of magnitude for each phantom over the range of acquisition parameters (0.30 and 21.0 mGy for a 10-year-old with 80 kVp, 10 mAs, and 0.8 second and with 140 kVp, 160 mAs, and 0.8 second, respectively). The volumetric anthropomorphic CT dose index for newborn phantoms was twice that for adult phantoms acquired similarly. The rod source dose was 0.03 mGy (3-minute scan). Although CT noise varied substantially among acquisition parameters, its contribution to PET noise was minimal and yielded only a 2% variation in PET noise. In a pediatric phantom, PET images generated by using CT performed with 80 kVp and 5 mAs for attenuation correction were visually indistinguishable from those generated by using CT performed with 140 kVp and 128 mAs. With very-low-dose CT (80 kVp, 5 mAs) for the adult phantom, undercorrection of the PET data resulted. CONCLUSION: For pediatric patients, adequate attenuation correction can be obtained with very-low-dose CT (80 kVp, 5 mAs, 1.5:1 pitch), and such correction leads to a 100-fold dose reduction relative to diagnostic CT. For adults undergoing CT with 5 mAs and 1.5:1 pitch, the tube voltage needs to be increased to 120 kVp to prevent undercorrection.
13
A combined PET/CT scanner for clinical oncology.
Thomas Beyer, D.W. Townsend, T. Brun et al. · PubMed · 2000 · 1.6K citations
Attenuation correction for a combined 3D PET/CT scanner
Paul E. Kinahan, D.W. Townsend, Thomas Beyer et al. · Medical Physics · 1998 · 933 citations
Corinna Bürger, Gerhard W. Goerres, S. Schoenes et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2002 · 425 citations