Lasers in Surgery and Medicine · 1997 · 33 citations · 24 references
EngineeringBiomedical EngineeringSurgeryBiomedical OpticsTissue EngineeringWound HealingBiomedical Laser ApplicationsLaser SurgerySurgical Wound HealingWound AssessmentWound Healing ResponseWound ManagementHigh-power Laser DiodesHigh-power Semiconductor LasersLaser - Material InteractionNd:yag Laser TreatmentPrimary Wound RepairTensile StrengthWound StrengthWound Tensile Strength
BACKGROUND AND OBJECTIVE: The laser-tissue interaction of a high power semiconductor diode laser was compared to the continuous wave neodymium yttrium aluminum garnet (Nd:YAG) laser by evaluating primary wound healing of cutaneous incisions in rats. STUDY DESIGN/MATERIALS AND METHODS: Full thickness incisions were made in rat skin using a diode laser (805 nm, 10 W, contact mode), an Nd:YAG laser (1,064 nm, 10 W, contact mode), and a stainless steel scalpel blade (control). In situ wound breaking strength measurements were obtained at 7, 14, and 21 days using a specially designed tensiometer. Cross sectional area of non-disrupted wounds was calculated in two groups prior to testing to allow for calculation of tensile strength. Blinded histopathologic analysis was also performed. RESULTS: Analysis of variance (P < or = 0.05) was used to determine differences in breaking strengths and tensile strengths due to incision method. There was no significant difference in the breaking strengths (group 1) or tensile strengths (groups 2 and 3) of the diode and Nd:YAG laser incisions. As predicted, breaking strengths and tensile strengths of scalpel blade incisions were significantly greater than those of incisions made with laser energy. Histopathologic evaluation revealed that through day 14, the degree of inflammation and collagen production was similar for diode and Nd:YAG laser incisions. Laser incisions had greater inflammation and a lag in fibroblast invasion and collagen production compared with scalpel incisions. By day 21, all incisions were similar in fibroblast population and collagen production, but laser incisions had slightly more inflammation than scalpel incisions. CONCLUSION: In the primary wound healing model described, the tissue effect, cellular response, and development of wound strength were essentially the same for the high power diode laser at 10 W and the Nd:YAG laser at 10 W.
24
Wound Healing: Biochemical and Clinical Aspects
Ricky P. Clay · Mayo Clinic Proceedings · 1993 · 535 citations
The Healing of Rat Skin Wounds
Stanley Μ. Levenson, Erving F. Geever, L. V. CHOWLEY et al. · Annals of Surgery · 1965 · 473 citations
Treatment of Tracheobronchial Lesions by Laser Photoresection
Jean‐Francois Dumon, E Reboud, Louise Garbe et al. · CHEST Journal · 1982 · 392 citations
Medicine, Otolaryngology, Surgery +11
Bronchoscopic management of tracheal lesions using the neodynium yttrium aluminium garnet laser.
L Toty, C Personne, A Colchen et al. · Thorax · 1981 · 221 citations · Full text