AV Nodal Ablation and Pacemaker Implantation Improves Hemodynamic Function in Atrial Fibrillation

Yoshihide Takahashi, Yoshito Iesaka, Atsushi Takahashi, Tomoo Harada, Takeshi Mitsuhashi, Kinya Shirota, Koichiro Kumagai, Norihito Nuruki, Takayoshi Shiraishi, Junichi Nitta,

Pacing and Clinical Electrophysiology · 2003 · 19 citations · 33 references

Concepts

Abstract

In drug refractory and highly symptomatic atrial fibrillation (AF) patients, hemodynamic effects of AV node ablation and pacing therapy (APT) were evaluated. Thirty-eight patients with drug refractory and symptomatic AF, underwent APT in eight centers in Japan. The outcome of this therapy was assessed in terms of quality-of-life, cardiac performance measured by echocardiogram, and plasma ANP and BNP levels before and after APT. Quality-of-life assessed by self-administered semi-quantitative questionnaires: WHO QOL 26 (3.0 +/- 0.5 vs 3.4 +/- 0.6, P < 0.01) and the Symptom Checklist: Frequency Scale (1.6 +/- 0.6 vs 0.7 +/- 0.7, P < 0.01) and Severity Scale (1.3 +/- 0.4 vs 0.6 +/- 0.6, P < 0.01), improved significantly 6 months after APT. Ejection fraction (EF) by echocardiogram improved 1 week after APT (59.0% +/- 13.3% vs 63.3% +/- 11.6%, P = 0.02). Plasma ANP levels in the group of ANP > 40 pg/mL at enrollment significantly decreased 1 month later (P = 0.03), and plasma BNP levels in the group of BNP > 20 pg/mL at enrollment significantly decreased 1 month later (P < 0.01). In conclusion, APT has beneficial hemodynamic effects, and plasma BNP levels can predict the most optimal candidates for ablation and pacing therapy.

References

33