Early Diagnosis of Abscess in Aortic Bioprosthetic Valve by 18F-Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography

Ludivine Saby, Yvan Le Dolley, Olivia Laas, L. Tessonnier, Serge Cammilleri, Jean‐Paul Casalta, Didier Raoult, Gilbert Habib, Franck Thuny

Circulation · 2012 · 22 citations · 3 references

Concepts

Abstract

A 69-year-old woman, with an aortic bioprosthetic valve implanted 2 years before, was referred to our department because of a suspicion of endocarditis.She had experienced fever for 1 week, and Haemophilus parainfluenza was identified in 1 blood culture.The total white blood count (WBC) was 12ϫ10 9 /L, and the erythrocyte sedimentation rate (ESR) was 60 mm.The first transthoracic and transesophageal echocardiographic (TEE) studies were considered as normal.However, the 18F-fluorodeoxyglucose positron emission tomography-computed tomography (18F-FDG PET-CT), performed the day after, revealed an intense fixation at the level of the bioprosthetic valve.Then, a treatment with ceftriaxone and gentamicin was started.Six days later, although fever persisted and ESR remained elevated, a second TEE showed the emergence of a periprosthetic abscess without any dehiscence (Figure 1 and Movies I and II).The lesions were confirmed during surgery performed thereafter.

References

3