Development of Under-sodium Three-dimensional Visual Inspection Technique Using Matrix-arrayed Ultrasonic Transducer

Hirokazu Karasawa, Mamoru Izumi, Takehiko Suzuki, Satoshi Nagai, Masaaki Tamura, Shyuuichi FUJIMORI

Journal of Nuclear Science and Technology · 2000 · 55 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

We have developed an advanced under-sodium ultrasonic visual inspection technique in order to observe in-vessel structures in a Fast Breeder Reactor (FBR) whose reactor vessel is filled with opaque liquid sodium. The final goal of this work is achievement of resolution equivalent to that of an image obtained by optical fiber scope. The under-sodium ultrasonic visualizing system consists of a matrix-arrayed transducer and a signal- processing device. The matrix-arrayed transducer, in which 36x36 piezoelectric elements are arranged with 5 mm interval and sealed by a thin metal diaphragm, can realize a 3-dimensional image with high resolution. Regarding signal processing, the 3-dimensional image synthetic processing and the cross correlation processing for the purpose of improving S/N ratio of ultrasonic echoes are implemented on a high-speed parallel processor. Under-sodium imaging test was carried out, and it was confirmed that a 3-dimensional image of the blind target, which was prepared without information beforehand, could be visualized clearly with less than 2.0 mm resolution under-sodium.

References