Abstract

BACKGROUND: Continuous subcutaneous insulin infusion (CSII) patients experience switches of pump systems on a regular basis. We investigated the impact of transition from older pumps to the Accu-Chek(®) Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) on a patient's glycemic control and diabetes management. PATIENTS AND METHODS: In total, 299 patients (172 female, 127 male; mean±SD age, 39.4±15.2 years; CSII duration, 7.0±5.2 years) were enrolled by 61 European sites into this uncontrolled prospective trial. Glycemic control, safety, and diabetes management parameters were measured at baseline and after 3 and 6 months. Changes from baseline were analyzed. RESULTS: After transition to the new insulin pump, mean±SD hemoglobin A1c (HbA1c) values decreased from 7.8±1.1% (baseline) to 7.7±1.1% (end point). The proportion of patients with HbA1c <7.0% was slightly higher at the end of the study (29.6%) than at baseline (25.2%), whereas the proportion of patients with HbA1c >8.0% decreased (baseline, 36.2%; end point, 32.7%; P<0.05). The number of hypoglycemic episodes (blood glucose<70 mg/dL) improved slightly during the study (baseline, 40.4±34.0 events/quarter; end point, 39.2±33.9 events/quarter). Glycemic control improved significantly in the group with an initial HbA1c >8.0% (-0.46%; P<0.001) and remained solidly stable in the group with an initial HbA1c <7% (+0.04%; not significant). Short-term (<3 years) pump users (n=48) had a larger HbA1c decrease (-0.40%) than long-term (≥3 years) users (n=251) (-0.07%; P<0.05). The number of blood glucose measurements increased (3.7±1.9/day vs. 4.4±1.8/day; P<0.05), whereas the number of insulin boluses decreased (5.1±1.9/day vs. 4.6±1.5/day; P<0.05) during the study. CONCLUSIONS: Transition from older pump systems to the Accu-Chek Combo system in a large patient population resulted in stable glycemic control with significant improvements in HbA1c in patients with unsatisfactory baseline HbA1c and shorter pump use. Increased frequency of self-monitoring of blood glucose and decrease of bolus frequency could suggest a more confident diabetes management and a reduced need for correction boluses.

References

13