Journal of Applied Physiology · 2006 · 20 citations · 27 references
MedicineOtolaryngologyPhysiologyPulmonologySleep MedicineVentilationAirway AssessmentMechanical VentilationPositive End-expiratory PressureRespiratory PathophysiologySleep-disordered BreathingSleep-related Breathing DisordersAirflow MonitoringFlow-resistance RelationshipNon-rapid Eye Movement Sleep EffectsPolysomnographic DiagnosisSleep Apnea SyndromeSleep-related Breathing PhysiologyUpper Airway MechanicsUpper Airway Patency
To examine the dynamic modulation of upper airway (UA) function during sleep, we devised a novel approach to measuring the critical pressure (Pcrit) within a single breath in tracheostomized sleep apnea patients. We hypothesized that the UA continuously modulates airflow dynamics during transtracheal insufflation. In this study, we examine tidal pressure-flow relationships throughout the respiratory cycle to compare phasic differences in UA collapsibility between closure and reopening. Five apneic subjects (with tracheostomy) were recruited (2 men, 3 women; 18-50 yr; 20-35 kg/m2; apnea-hypopnea index >20) for this polysomnographic study. Outgoing airflow through the UA (face mask pneumotachograph) and tracheal pressure were recorded during brief transtracheal administration of insufflated airflow via a catheter. Pressure-flow relationships were generated from deflation (approaching Pcrit) and inflation (after Pcrit) of the UA during non-rapid eye movement sleep. During each breath, UA function was described by a pressure-flow relationship that defined the collapsibility (Pcrit) and upstream resistance (Rus). UA characteristics were examined in the presence and absence of complete UA occlusion. We demonstrated that Pcrit and Rus changed dynamically throughout the respiratory cycle. The UA closing pressure (4.4 +/- 2.0 cm H2O) was significantly lower than the opening pressure (10.8 +/- 2.4 cm H2O). Rus was higher for deflation (18.1 +/- 2.4 cm H2O x l(-1) x s) than during inflation (7.5 +/- 1.9 cm H2O x l(-1) x s) of the UA. Preventing occlusion decreases UA pressure-flow loop hysteresis by approximately 4 cm H2O. These findings indicate that UA collapsibility varies dynamically throughout the respiratory cycle and that both local mechanical and neuromuscular factors may be responsible for this dynamic modulation of UA function during sleep.
27
Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects
Shiroh Isono, John E. Remmers, Atsuko Tanaka et al. · Journal of Applied Physiology · 1997 · 526 citations
Medicine, Anatomy, Otolaryngology +14
Upper airway pressure-flow relationships in obstructive sleep apnea
Philip L. Smith, Robert A. Wise, Avram Gold et al. · Journal of Applied Physiology · 1988 · 442 citations
Medicine, Otolaryngology, Physiology +17
Collapsibility of the Upper Airway at Different Concentrations of Propofol Anesthesia
Peter R. Eastwood, Peter R. Platt, Kelly Shepherd et al. · Anesthesiology · 2005 · 363 citations
Medicine, Anesthesiology, Anesthesia +16