Journal of Hand Surgery (European Volume) · 1992 · 31 citations · 12 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryElbow SurgeryMicrosurgeryOrthopedicsHand SurgeryJoint SurgeryLigament ReconstructionTendon RepairFunctional TestingHorizontal Mattress SuturesSurgical Ligament RepairThumb Ulnar Collateral Ligament InjuryThumb Ulnar Collateral Ligament Reconstruction
25 patients were assessed following repair of an acutely ruptured ulnar collateral ligament of the thumb metacarpo-phalangeal joint. The patients were divided into two groups, repaired by either a horizontal mattress suture using 4/0 polybutylate (nine patients), or a pre-fashioned steel wire (16 patients). Assessment included a physical examination and functional testing at a mean of 12.9 months (range 4-36 months) after the operation. Both techniques were equally effective, and the use of the more expensive steel wire, while technically satisfying and easy to perform, offers no clinical advantage over simple suture. This pre-fashioned steel wire is, however, recommended in those cases with an avulsion fracture or where distal avulsion of the ligament is associated, since the technique allows easy secure reduction.
12
Archives of Physical Medicine and Rehabilitation
Journal of Sound and Vibration · 1976 · 5.5K citations
Grip and pinch strength: normative data for adults.
Virgil Mathiowetz, Nancy Kashman, Gloria Volland et al. · PubMed · 1985 · 2.2K citations
David P. Green, Austin D. Potenza, Paul Silverstein · Plastic & Reconstructive Surgery · 1983 · 1.5K citations
Medicine, Surgery, Elbow Surgery +6