Measurement variability of carotid atherosclerosis: real-time (B-mode) ultrasonography and angiography.

Daniel H. O’Leary, Fred A. Bryan, Marta W. Goodison, Matthew D. Rifkin, Raymond Gramiak, Marshall R. Ball, M. Gene Bond, Rebecca Dunn, B. B. Goldberg, James F. Toole

Stroke · 1987 · 95 citations · 3 references

Concepts

Abstract

To quantify the within- and between-reader agreement of carotid B-mode ultrasonography and angiography interpretation, images from 117 patients examined by both modalities were read multiple times. Angiographic measurements were more reproducible than those of B-mode scans for all parameters except lesion width, but variations for B-mode scan measurements were similar to those for angiographic measurements. Within-reader agreement on the presence of ulceration was substantial for both modalities, whereas between-reader agreement was poor for B-mode scan and only moderate for angiography.

References

3