Annals of Plastic Surgery · 2008 · 35 citations · 15 references
MedicineRadiologySurgeryDiagnostic ImagingDiagnostic RadiologyUltrasonographyComputed TomographyDoppler UltrasonographyDoppler UltrasoundVascular ImagingDeep Inferior Epigastric Perforator Flap ReconstructionIntraoperative Doppler UltrasonographyIntraoperative Doppler UltrasoundMarkingsMultidetector Computed TomographyPerforator AnatomyPerforator Flap AnatomyPerforator Vessel Anatomy
BACKGROUND: Multidetector-row computed tomography (MDCT) has been recently introduced to detect the perforator vessels. The aim of this study is to compare the MDCT with Doppler ultrasound and assess the usefulness of the MDCT for the preoperative planning. METHODS: Five healthy adult men were first assessed for the perforators and marked with rubber using the Doppler ultrasound before MDCT was performed. Using these images, the number and the location of the perforator were evaluated. RESULTS: We could detect 83 perforators on five cases, while could detect 35 perforators by the Doppler ultrasound. We measured the distance from the fascia perforating points to rubber markings points. It ranged from 0 to 22.47 mm (7.62 mm on average). CONCLUSION: MDCT angiography is useful for preoperative planning of deep inferior epigastric artery perforator flap at the point of more accurate anatomical findings and clear images of perforator vessels compared to the findings using Doppler ultrasound.
15
Doppler flowmetry in the planning of perforator flaps
Phillip Blondeel, Guy Beyens, Raymond Verhaeghe et al. · British Journal of Plastic Surgery · 1998 · 351 citations
Medicine, Plastic Surgery, Surgery +14