Neurophotonics · 2014 · 84 citations · 36 references
MedicineNeurosurgerySurgeryBiomedical ImagingBiomedical OpticsDiagnostic ImagingBrain ImagingCerebral Blood FlowCerebral Perfusion MonitoringCerebral Blood Flow QuantificationIntraoperative Cerebral MonitoringLaser Speckle ImagingMedical Image RegistrationMotion ArtifactsRegional Cerebral Blood FlowRetrospective Motion CorrectionSpeckle Contrast
Although multiple intraoperative cerebral blood flow (CBF) monitoring techniques are currently available, a quantitative method that allows for continuous monitoring and that can be easily integrated into the surgical workflow is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging technique with a high spatiotemporal resolution that has been recently demonstrated as feasible and effective for intraoperative monitoring of CBF during neurosurgical procedures. This study demonstrates the impact of retrospective motion correction on the quantitative analysis of intraoperatively acquired LSCI images. LSCI images were acquired through a surgical microscope during brain tumor resection procedures from 10 patients under baseline conditions and after a cortical stimulation in three of those patients. The patient's electrocardiogram (ECG) was recorded during acquisition for postprocess correction of pulsatile artifacts. Automatic image registration was retrospectively performed to correct for tissue motion artifacts, and the performance of rigid and nonrigid transformations was compared. In baseline cases, the original images had [Formula: see text] noise across 16 regions of interest (ROIs). ECG filtering moderately reduced the noise to [Formula: see text], while image registration resulted in a further noise reduction of [Formula: see text]. Combined ECG filtering and image registration significantly reduced the noise to [Formula: see text] ([Formula: see text]). Using the combined motion correction, accuracy and sensitivity to small changes in CBF were improved in cortical stimulation cases. There was also excellent agreement between rigid and nonrigid registration methods (15/16 ROIs with [Formula: see text] difference). Results from this study demonstrate the importance of motion correction for improved visualization of CBF changes in clinical LSCI images.
36
elastix: A Toolbox for Intensity-Based Medical Image Registration
Stefan Klein, Marius Staring, Keelin Murphy et al. · IEEE Transactions on Medical Imaging · 2009 · 4.4K citations
Dynamic Imaging of Cerebral Blood Flow Using Laser Speckle
Andrew K. Dunn, Hayrünnisa Bolay, Michael A. Moskowitz et al. · Journal of Cerebral Blood Flow & Metabolism · 2001 · 824 citations · Full text
Medicine, Neurology, Neuroscience +17