Acta Orthopaedica Scandinavica · 1994 · 26 citations · 5 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsBone BiomechanicsGait AnalysisGait BiomechanicsLower Limb BiomechanicsPressure DistributionPressure RedistributionClinical Gait AnalysisFoot Pressure MeasurementGait Analysis After Knee ArthroplastyGait Pressure AnalysisKnee Extension StrengthPeak Pressure AnalysisPeak Pressure LoadsPressure-time Integral
We evaluated pressure distribution patterns under the feet during gait in 20 patients after resection of malignant bone tumor and endoprosthetic replacement of the distal femur. In all cases, a modular cementless, hinged prosthesis had been used. The examination was performed after 4 (1-6) years. Shortened contact phase, decreased peak pressure, and reduced force-time integral during gait analysis were observed on the operated side. Peak pressure in the heel and the toe regions was decreased and the load (force-time integral) in the metatarsal heads and the big toe regions was reduced. There was a positive correlation between load under the foot and knee extension strength, measured isokinetically.
5
Limb Salvage in Musculoskeletal Oncology.
Jonathan Cohen · Journal of Bone and Joint Surgery · 1988 · 284 citations
Reliability of pressure measurements: the EM ED F system
Janet Hughes, Lawrence E Pratt, Keith Linge et al. · Clinical Biomechanics · 1991 · 228 citations
A Modular Femur-Tibia Reconstruction System
R. Kotz, Peter Ritschl, J Trachtenbrodt · Orthopedics · 1986 · 135 citations