IEEE Transactions on Power Electronics · 2013 · 135 citations · 26 references
EngineeringElectrical EngineeringCircuit TheoryPower ElectronicsRenewable Energy SystemsAdaptive ControlDc-ac InvertersDistributed Energy ResourcesPower Grid AnalysisPower QualityPower System StabilityControl System RobustnessGrid-connected InvertersGrid-tied InvertersHarmonic ReductionInverter SystemsPassive DampingPassive Damping DevicesSystem Stability
In order to minimize the effect of the grid harmonic voltages, harmonic compensation is usually adopted for a grid-tied inverter. However, a large variation of the grid inductance challenges the system stability in case a high-order passive filter is used to connect an inverter to the grid. Although in theory, an adaptive controller can solve this problem, but in such a case the grid inductance may need to be detected online, which will complicate the control system. This paper investigates the relationship between the maximum gain of the controller that still keeps the system stable and the Q-factor for a grid-tied inverter with an RL series or an RC parallel damped high-order power filter. Then, a robust passive damping method for LLCL-filter-based grid-tied inverters is proposed, which effectively can suppress the possible resonances even if the grid inductance varies in a wide range. Simulation and experimental results are in good agreement with the theoretical analysis.
26
Xiaoming Yuan, W. Merk, H. Stemmler et al. · IEEE Transactions on Industry Applications · 2002 · 809 citations
Xiaoming Yuan, Jost Allmeling, W. Merk et al. · 2002 · 666 citations