Archives of Ophthalmology · 1979 · 36 citations · 5 references
MedicineOphthalmologySurgeryClinical OptometryOphthalmic SurgeryRefractive SurgeryAstigmatism CorrectionCorneal TransplantationLens SurgeryPostoperative Refractive OutcomesPreoperative Refractive EvaluationRefractive ErrorDonor Cornea QualityGraft Size SelectionIntraocular Pressure ElevationIntraocular Pressure ManagementIntraocular Pressure ReductionOptical KeratoplastyPostoperative AstigmatismRandomized Clinical Trials
Forty-six patients were examined in a prospective, randomized clinical study to compare the use of the same size trephine on both donor and recipient with the use of a 0.5-mm larger trephine on the donor in aphakic keratoplasty and in keratoplasty combined with lens extraction. The results showed no statistically significant difference in refractive error, either in spherical equivalents or in astigmatism. The larger donor tissue may have some value in reducing high plus-refractive error and in reducing intraocular pressure after surgery.
5
Transplant Size and Elevated Intraocular Pressure
Thom J. Zimmerman · Archives of Ophthalmology · 1978 · 101 citations
Medicine, Ophthalmology, Surgery +15
Variation in Corneal Graft Size Related to Trephine Technique
Randall J. Olson · Archives of Ophthalmology · 1979 · 76 citations
Medicine, Plastic Surgery, Surgery +13
Randall J. Olson · Archives of Ophthalmology · 1978 · 40 citations
Medicine, Ophthalmology, Surgery +14