Publication | Closed Access
Some Measurements in Subcooled Flow Boiling of Refrigerant-113
11
Citations
0
References
1991
Year
Heat Transfer ProcessEngineeringMixed ConvectionHeat ExchangerFluid MechanicsLiquid Phase TemperatureSubcooled Flow BoilingWall Heat FluxGas-liquid FlowExperimental ThermodynamicsThermodynamicsHeat TransferMultiphase FlowThermal EngineeringConvective Heat TransferVertical Annular ChannelBoilingRefrigeration
Measurements of local vapor phase residence time fraction, liquid phase temperature, and heated wall temperature were carried out in subcooled flow boiling of Refrigerant-113 through a vertical annular channel. Data are reported for two fluid mass velocities and two pressures over a range of wall heat flux. Estimates of typical vapor bubble size and velocity are given. Some comparisons with a one-dimensional two-fluid model of subcooled boiling flow are also presented.