Radiology · 1958 · 18 citations · 0 references
MedicineNuclear EngineeringRadiation DosimetryRadiation MeasurementRadiation SafetyAbsorbed DoseDosimetry InstrumentationPatient-specific DosimetryRadiation Dose MeasurementThree-dimensional Dose DistributionDose Distribution CalculationsPatient-specific Dose CalculationPoint SourcesThree-dimensional Dose Calculation
Generally the dose produced by implanting radioactive point sources within a patient is calculated by either the Paterson-Parker or the Quimby system. These systems assume a fixed distribution of sources, non-uniform and uniform respectively. Because of mechanical and physiological difficulties, however, these distributions are difficult to obtain. The purpose of this paper is to present a method by which the dose distributions produced by any random arrangement of radioactive sources can be computed and tabulated automatically. All possible positions of the sources are located in a three dimensional Cartesian co-ordinate system with interspaces of a.5 em. The X and Yeo-ordinates of each source are expressed in terms of this lattice and this distribution may be extended for 11 em. in each co-ordinate. The Z co-ordinate is distance from the plane under consideration (Fig. 1.). The dose produced by each source is considered to be a function of the inverse-square law only. Such a dose is regarded as insignificantly small beyond 4.5 cm., as it is only 5 per cent of the dose at 1 em. These data are tabulated and transferred to punch cards. The dose contributions at a.5-cm. intervals in the X co-ordinate are tabulated on separate cards. Such cards are coded for each a.5-em. separation in the Y co-ordinate. Thus the data for the X-Yplane through the source is contained on 19 cards, referred to as a planar deck. The complete dose distribution throughout the volume of the sphere of influence of a source is given by 9 planar decks or a volume deck of 147 cards. There are volume decks (19)2 to include all possible source locations. Each deck is coded with the X and Y co-ordinate of the sources. The Z co-ordinate varies for each planar deck. The distribution of the implanted radioactive sources in the patient is determined by stereographic roentgenograms or by a tube-shift method. The sources are located in the Cartesian co-ordinate system to the nearest 2.5 mm. The various planar decks are chosen for each source and are put in order by a sorting machine. The dose to any plane produced by radioactive sources within the implant is calculated by summing the dose from each source to that plane (Fig. 2). The percentage dose rates are then automatically added, tabulated and printed for that particular plane by the accounting machine. The percentages are plotted on a Cartesian grid and the points of equal dose are joined, giving the dose distribution for a complete plane (Fig. 3).