Investigative Ophthalmology & Visual Science · 2006 · 206 citations · 16 references
MedicineSurgeryAnterior SegmentOphthalmic SurgeryTissue EngineeringCorneal AnatomyCorneal ImagingCorneal OpticsCorneal PhysiologyCorneal Tissue EngineeringCorneal Wound HealingConfocal Microscopy AssessmentCorneal BiomaterialsCorneal GraftingCorneal Implant BiomaterialsCross-linked Collagen BiomaterialsMatrix Cross-linkingPostoperative HazeTear Film Imaging
PURPOSE: To develop a simple corneal substitute from cross-linked collagen. METHODS: Porcine type I collagen (10%; pH 5), was mixed with 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The final homogenous solution was molded to corneal dimensions, cured, and then implanted into rabbits and minipigs by lamellar keratoplasty. The implants were followed for up to 6 months after surgery. Clinical examinations of the cornea included detailed slit lamp biomicroscopy, in vivo confocal microscopy, topography and esthesiometry for nerve function. Histopathologic examinations were also performed on rabbit corneas harvested after 6 months. RESULTS: Cross-linked collagen (refractive index, 1.35) had optical clarity superior to human corneas. Implanted into rabbit and porcine corneas, only 1 of 24 of the surgical corneas showed a slight haze at 6 months after surgery. All other implants showed no adverse reactions and remained optically clear. Topography showed a smooth surface and a profile similar to that of the contralateral nonsurgical eye. The implanted matrices promoted regeneration of corneal cells, tear film, and nerves. Touch sensitivity was restored, indicating some restoration of function. The corneas with implants showed no significant loss of thickness and demonstrated stable host-graft integration. CONCLUSIONS: Collagen can be adequately stabilized, using water soluble carbodiimides as protein cross-linking reagents, in the fabrication of corneal matrix substitutes for implantation. The simple cross-linking methodology would allow for easy fabrication of matrices for transplantation in centers where there is a shortage of corneas, or where there is need for temporary patches to repair perforations in emergency situations.
16
Corneal blindness: a global perspective.
John P. Whitcher, Muthiah Srinivasan, Madan Prasad Upadhyay · PubMed · 2001 · 1.5K citations
An SV40-immortalized human corneal epithelial cell line and its characterization.
Kaoru Araki‐Sasaki, Yuichi Ohashi, T Sasabe et al. · PubMed · 1995 · 738 citations
Long-term graft survival after penetrating keratoplasty
Robert W. Thompson, Marianne O. Price, Patrick Bowers et al. · Ophthalmology · 2003 · 607 citations
Medicine, Ophthalmology, Surgery +10