Detection of a polarization imbalance in reverberation chambers and how to remove it by polarization stirring when measuring antenna efficiencies

Per‐Simon Kildal, Charlie Carlsson

Microwave and Optical Technology Letters · 2002 · 92 citations · 8 references

Concepts

TL;DR

Radiation efficiency of small antennas can be accurately measured in reverberation chambers. This Letter investigates the cause of polarization imbalance in reverberation chamber measurements and proposes using three orthogonal fixed antennas for polarization stirring to eliminate it. The technique averages transmitted power between the test antenna and fixed antennas, employing three orthogonal fixed antennas for polarization stirring. Results vary significantly with the test antenna’s orientation and polarization. © 2002 Wiley Periodicals, Inc.; DOI 10.1002/mop.10398.

Abstract

Abstract It has previously been shown that the radiation efficiency of small antennas can be measured with good accuracy in reverberation chambers. The results are obtained by averaging several measurements of the transmitted power between the antenna under test and a fixed antenna, both located inside the chamber. Further investigations have shown that the results depend strongly on the orientation of the antenna under test and thereby on its polarization. The present Letter explains why it is like this, and how this imbalance can be removed by polarization stirring, that is, by using three orthogonal fixed antennas instead of one. © 2002 Wiley Periodicals, Inc. Microwave Opt Technol Lett 34: 145–149, 2002; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.10398

References

8