Dental Materials Journal · 2010 · 29 citations · 4 references
DentistryDental Materials ScienceDental MaterialsProsthodontic MaterialsStone ConservationDigital Impression TechniquesImpression MaterialsAccuracyAlginateAlginate Impression MaterialDimensional AccuracyDimensional Accuracy AssessmentDisinfection Of ImpressionsSprayStorage Effects On Impression Accuracy
This study investigated the effects of storing impressions for 3 hours after spraying them with a disinfectant solution on dimensional change and deformation of maxillary edentulous stone models. Three brands of alginate impression materials, characterized by a small degree of contraction in 100% relative humidity, were used. The spray disinfectants used were 1% sodium hypochlorite solution and 2% glutaraldehyde solution. A stone model taken from an impression that had not been sprayed or stored was prepared as a control. The results indicated that the differences in dimensional change between the control and disinfected stone models were less than 24 mum, and that no deformation was observed in the stone models.
4
P.L. Fan · The Journal of the American Dental Association · 1991 · 39 citations
Hisako Hiraguchi, Hisami Nakagawa, Mitsuru WAKASHIMA et al. · Dental Materials Journal · 2005 · 24 citations · Full text