EngineeringMaterials EngineeringMaterials ScienceCeramic MaterialsCeramicsRadiation ProtectionCeramic Nuclear MaterialsControl ValvesRadiation-resistant MaterialsCeramic Membrane FabricationLife Cycle EngineeringPneumatic ValvesPressure Safety ValvesSafety Valve DesignSafety ValvesTitanium MaterialsTitanium Oxides
A fast-closing valve system has been designed and fabricated in order to protect the vacuum of the synchrotron radiation beam line and that of the 2.5 GeV storage ring from a sudden vacuum failure at the downstream end of the beam line. Upon the detection of a failure the valve closes within 11.9 ms by pneumatic pressure on a drive piston in a cylinder. Within the last 3.7 ms of the closing time the downward movement of the blade is decelerated so as to reduce the closing shock. A hard TiN ceramic membrane is coated on the surface of the titanium blade. On the surface of a stainless steel aperture, an Al/sub 2/O/sub 3/-TiO/sub 2/ ceramic membrane (less hard than TiN) is coated in order to attain low conductance and smooth movement of the blade. This ensures a low leak rate of 0.135 torr l/s and a long life cycle of the mechanism (more than 8000 times).< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
6
Front ends for the Photon Factory beam lines
Shigeru Sato, T. Koide, Y Morioka et al. · Nuclear Instruments and Methods in Physics Research · 1983 · 24 citations