Dental Research Journal · 2012 · 85 citations · 29 references
DentistryAnatomyOral RadiologyClinical AnatomyDental RadiologyMaxillofacial ImagingDental AnatomyImaging AssessmentJaw Function AssessmentTemporomandibular Joint AnatomyTemporomandibular Joint ImagingTemporomandibular Joint RadiographyCondylar PositioningJoint Space LandmarksMandibular Condyle AssessmentMandibular Condyle ImagingMandibular Condyle PositionPaired T-testTemporomandibular Joint Space AssessmentTemporomandibular Joint Tomography
BACKGROUND: The optimal position of the condyle in glenoid fossa is a fundamental question in dentistry. There is no quantitative standard for the optimal position of mandibular condyle in the glenoid fossa in our population. The purpose of this study is to assess the position of the condyle by cone beam computed tomography (CBCT) images in patient with normal function of temporomandibular joint (TMJ). MATERIALS AND METHODS: In this cross-sectional study, CBCT images of 40 class I skeletal patients (15 males and 25 females) without history of TMJ disorders were selected. Next, the anterior, superior and posterior joint spaces (Ajs, Sjs, Pjs) were measured on the two true central sagittal slices. Then medial (M) and lateral (L) joint spaces on true coronal view were measured in the right and left sides, separately. After that, P/A ratio, S/A ratio and M/L ratio were calculated. Finally, a paired t-test and independent samples t-test were employed for analysis. RESULTS: The centric position of the condyle in glenoid fossa was more common (92.5%) than other positions. Significant differences in Ajs, Sjs, Pjs, Mjs and Ljs values between two sides were observed (P ≤ 0.05). Additionally, Sjs showed statistically significant differences between the sexes (P = 0.05). P/A ratio and S/A ratio had significant differences between two sides but not between those sexes. CONCLUSION: The assessment of joint spaces in right and left sides should be done independently. Overall, the measured joint spaces except Sjs are not different in two sexes. The data from this study could be a useful and comparable reference for the clinical assessment of condylar position in patients with normal functional joints.
29
Accuracy in measurement of distance using limited cone-beam computerized tomography.
Kaoru Kobayashi, Shinji Shimoda, Yoichi Nakagawa et al. · PubMed · 2004 · 410 citations
Dentistry, Oral Radiology, Radiology +17
Mark M. Tasaki, Per‐Lennart Westesson, Annika Isberg et al. · American Journal of Orthodontics and Dentofacial Orthopedics · 1996 · 406 citations · Full text