SPE Annual Technical Conference and Exhibition · 2002 · 26 citations · 11 references
EngineeringPetroleum EngineeringProduction EngineeringReservoir CharacterizationReservoir EngineeringFormation TestingFractured Reservoir FlowGelsNaturally Fractured ReservoirsTreatment DesignFluid Properties CharacterizationGel TreatmentNaturally Fractured Reservoir TestingStandard Errors Of MeasurementWater Cut AnalysisWater Cut EffectsWell Productivity In Fractured Reservoirs
Abstract This paper demonstrates the connection between laboratory measurements and field results from gelant treatments in production wells at the naturally fractured Motatan field in Venezuela. Using a HPAM polymer with an organic crosslinker, laboratory corefloods revealed that under reservoir conditions, the gel provided oil and water residual resistance factors of 20 and 200, respectively. This gel was placed in several production wells in the Motatan field. In Well P-47, 1,000 bbl of this gel reduced the water cut from 97% to 64% and increased the oil production rate by 36%. The success of these treatments depends on the distance of gelant leakoff from the fracture face and the in situ residual resistance factors in the oil and water zones. Analyses were performed to determine these parameters, based on formation permeabilities, porosities, fluid saturations, fluid properties, fluid production rates, and pressure drops before, during, and after gelant placement. Accurate pressure drops before, during, and after gelant placement were particularly important. Sensitivity studies were performed to demonstrate their significance and the impact of measurement errors. A methodology is presented for optimizing the volume of gelant injected for these applications.
11
Gel Placement in Production Wells
Jenn‐Tai Liang, Regina Lee, R. S. Seright · SPE Production & Facilities · 1993 · 120 citations