Cancer · 1993 · 56 citations · 29 references
MedicineNuclear MedicineRadiologyDiagnostic Nuclear MedicineRadionuclide TherapyTherapeutic Nuclear MedicineEndocrine ImagingThyroid CancerThyroid ImagingThyroid ScintigraphyThyroid SurgeryThyroid Uptake StudiesDifferentiated Thyroid Cancer DiagnosisDifferentiated Thyroid Cancer ImagingIodine-123 ScintigraphyIodine-131 ScintigraphyRadionuclide Thyroid ScintigraphySensitivityThyroid Tumor ImagingThyroid-stimulating Hormone Stimulation
BACKGROUND: A prospective study was conducted to evaluate the use of iodine-131 sodium scintigraphy, thallium-201 chloride scintigraphy, and quantitative serum thyroglobulin estimation in the detection of differentiated thyroid carcinoma after thyroidectomy and iodine-131 sodium ablative therapy. METHODS: Thirty-one patients with a median age of 45.6 years (range, 20-73 years) were included in the study. After optimal endogenous thyroid-stimulating hormone stimulation (> 50 mU/ml), 53 pairs of iodine-131 and thallium-201 scans were performed. Concomitant serum thyroglobulin levels were available for 32 pairs of scans. The presence or absence of thyroid cancer was established by clinical, radiologic, and/or biopsy findings. RESULTS: The concordance between iodine-131 and thallium-201 scan findings in the presence of disease (25 scan sets) was 36%. The concordance in the absence of disease (28 scan sets) was 82%. Iodine-131 scanning was found to be significantly better (P < 0.05) than thallium-201 scanning, in terms of sensitivity (0.8 versus 0.6), specificity (0.96 versus 0.82), accuracy (0.89 versus 0.72), and the predictive value of a positive test (0.95 versus 0.75). The measurement of serum thyroglobulin had a low sensitivity (0.3) in the study but had a specificity of 1.0. CONCLUSION: It was concluded that iodine-131 sodium scintigraphy is superior to thallium-201 scintigraphy and serum thyroglobulin estimation for the detection of residual or metastatic differentiated thyroid carcinoma. However, the use of combined modalities provides a higher diagnostic yield. Thallium-201 scintigraphy was especially useful in cases in which iodine-131 scintigraphy was negative and quantitative thyroglobulin levels were elevated.
29
Ian Hay · Endocrinology and Metabolism Clinics of North America · 1990 · 637 citations
C. C. Boring, T. S. Squires, T. Tong · CA A Cancer Journal for Clinicians · 1991 · 621 citations · Full text
Ernest L. Mazzaferri, Robert L. Young, James E. Oertel et al. · Medicine · 1977 · 536 citations
Papillary carcinoma of the thyroid I. Developing pattern of metastasis
Shiro Noguchi, Akito Noguchi, Nobuo Murakami · Cancer · 1970 · 280 citations · Full text