Electric Machines & Power Systems · 1992 · 15 citations · 12 references
EngineeringElectrical EngineeringElectric MachinesMachine DesignMagnetic MaterialsInduction MachinesMagnetic Circuit AnalysisSynchronous MachinesFrame ModelsMagnetic Field CouplingMagnetic ModelingMagnetic Saturation AnalysisReactive Power ControlSaturationSynchronous Machine ModelingSynchronous Motors
Abstract This paper discusses the various approaches of representing saturation in the steady–state, two–axis (direct- and quadrature–axis) frame models of synchronous machines. In particular, the important role of the magnetic coupling between the direct-and quadrature axis (cross-magnetizing phenomenon), which is commonly neglected, is demonstrated. A new model and modified active and reactive power/load angle relationships, in which the effect of the cross-magnetizing phenomenon is included, are presented. Experimental verification of the accuracy of this model and these relationships and the importance of the inclusion of the cross-magnetizing effect in them are also reported in the paper.
12