European Journal Of Haematology · 2003 · 59 citations · 11 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyHematologic OncologyBone Marrow EvaluationBone Tumor ImagingCancer DetectionCancer DiagnosisHematologic MalignanciesMultiple Myeloma18F-fluorodeoxyglucose ImagingBone Marrow AssessmentBone Marrow Involvement AssessmentBone Marrow Lesion AssessmentMultiple Myeloma Of BoneMyeloma Bone DiseaseOccult MalignancySpecificity Of Skeletal Survey
OBJECTIVE: The extent of disease in patients with multiple myeloma or related conditions may be difficult to assess. In previous small studies, both FDG-PET (PET) and Tc-99m sestamibi scans (MIBI) have identified sites of occult disease in myeloma. METHODS: We reviewed the results for patients at our institution who have undergone PET and/or MIBI scans to assess myeloma. Concordance between the scans, ability to identify otherwise occult disease and impact on patient management was assessed. RESULTS: Thirty-six patients had > or =1 PET scan, 56 had > or =1 MIBI scan and 23 had concurrent PET and MIBI scans. MIBI detected additional sites to skeletal survey in 38 of 56 (68%) cases. PET detected additional sites to skeletal survey in 18 of 36 (50%) cases. MIBI generally detected more disease sites than PET. PET and MIBI were concordant in eight of 23 (35%) cases. The percentage plasma cell infiltrate within the marrow correlated with the number of sites detected by MIBI, but not by PET. In 23 of 69 cases (33%), scan results impacted on management, particularly by upstaging disease at diagnosis and by recognising subsequent disease progression. The results were also helpful for evaluating the presence of ongoing disease activity in previously irradiated sites remaining abnormal on skeletal survey following treatment. CONCLUSIONS: MIBI and PET are useful additional diagnostic tools for detecting otherwise occult sites of myeloma. The use of MIBI PET should particularly be considered in the evaluation of a patient with an early-stage plasma cell dyscrasia to exclude the presence of more extensive disease.
11
Robert A. Kyle, Philip R. Greipp · New England Journal of Medicine · 1980 · 453 citations
Medicine, Hematology, Oncology +16
Whole-body (18)F-FDG PET identifies high-risk myeloma.
Brian G.M. Durie, Alan D. Waxman, Allesandro D'Agnolo et al. · PubMed · 2002 · 276 citations
Diagnostic utility of FDG PET in multiple myeloma
Hossein Jadvar, Peter Conti · Skeletal Radiology · 2002 · 96 citations
Technetium-99m-MIBI versus fluorine-18-FDG in diffuse multiple myeloma.
Ayda M. El-Shirbiny, Henry Yeung, Massimo Imbriaco et al. · PubMed · 1997 · 50 citations