BJOG An International Journal of Obstetrics & Gynaecology · 2006 · 91 citations · 30 references
MedicineMaternal HealthObstetricsMaternal-fetal MedicinePrenatal DiagnosisUltrasonographyCongenital Heart DiseaseCongenital MalformationsFetal AnomaliesFetal Anomaly DetectionFetal EchocardiographyFetal ImagingCongenital Heart Disease DetectionCongenital Malformation DetectionFetal Anatomy EvaluationFetal Cardiac Anomaly DetectionFetal Ultrasound ScreeningNuchal Translucency ScreeningPrenatal Cardiac ScreeningPrenatal Congenital Anomaly Assessment
OBJECTIVE: To compare the rate of prenatal diagnosis of heart malformations between two policies of screening for heart malformations. DESIGN: Randomised controlled trial. SETTING: Six university hospitals, two district general hospitals. SAMPLE: A total of 39 572 unselected pregnancies randomised to either policy. METHODS: The 12-week policy implied one routine scan at 12 weeks including measurement of nuchal translucency (NT), and the 18-week policy implied one routine scan at 18 weeks. Fetal anatomy was scrutinised using the same check-list in both groups, and in both groups, indications for fetal echocardiography were ultrasound findings of any fetal anomaly, including abnormal four-chamber view, or other risk factors for heart malformation. In the 12-week scan group, NT >or=3.5 mm was also an indication for fetal echocardiography. MAIN OUTCOME MEASURE: Prenatal diagnosis of major congenital heart malformation. RESULTS: In the 12-week scan group, 7 (11%) of 61 major heart malformations were prenatally diagnosed versus 9 (15%) of 60 in the 18-week scan group (P= 0.60). In four (6.6%) women in the 12-week scan group, the routine scan was the starting point for investigations resulting in a prenatal diagnosis versus in 9 (15%) women in the 18-week scan group (P=0.15). The diagnosis was made <or=22 weeks in 5% (3/61) of the cases in the 12-week scan group versus in 15% (9/60) in the 18-week scan group (P=0.08). CONCLUSIONS: The prenatal detection rate of major heart malformations was low with both policies. The 18-week scan policy seemed to be superior to the 12-week scan policy, although the differences in prenatal detection rates were not statistically significant.
30
Congenital Heart Disease in 56,109 Births Incidence and Natural History
Shiela C. Mitchell, Sheldon B. Korones, H. Berendes · Circulation · 1971 · 1.3K citations · Full text
Medicine, Cardiology, Pediatrics +11
CONGENITAL HEART DISEASE: PREVALENCE AT LIVEBIRTH
Charlotte Ferencz, Judith D. Rubin, Robert McCarter et al. · American Journal of Epidemiology · 1985 · 1K citations
Medicine, Cardiology, Obstetrics +15
Detection of Transposition of the Great Arteries in Fetuses Reduces Neonatal Morbidity and Mortality
Damien Bonnet, Anna Coltri, Gianfranco Butera et al. · Circulation · 1999 · 767 citations · Full text
Medicine, Cardiology, Surgery +12
Improved Surgical Outcome After Fetal Diagnosis of Hypoplastic Left Heart Syndrome
Wayne Tworetzky, Doff B. McElhinney, V. Mohan Reddy et al. · Circulation · 2001 · 684 citations
Medicine, Cardiology, Surgery +16