Carbon monoxide production in ventilated premature infants weighing less than 1500 g.

Allen Fischer, Clark Ochikubo, Hendrik J. Vreman, David K. Stevenson

Archives of Disease in Childhood · 1987 · 10 citations · 6 references

DOIFull text

Open access

Concepts

Abstract

Mean pulmonary excretion rate of carbon monoxide in 13 premature babies on ventilators was significantly higher (p less than 0.001) than that of 19 healthy infants born at full term. This correlated with carboxyhaemoglobin concentrations in blood, indicating that the premature infants on ventilators produced abnormally large amounts of bilirubin.

References

6