1984 · 25 citations · 0 references
EngineeringAerospace EngineeringAerodynamicsFluid DynamicsHeat TransferAerodynamic TestingEngine TestingExperimental AerodynamicsTurbofan EnginesBlowdown SystemsHeat Transfer MechanismsThree-dimensional Computational Fluid DynamicsTurbine AerodynamicsTurbine Blade AerodynamicsTurbine CoolingTurbine DesignTurbines
A short duration (0.4 sec) test facility, capable of testing 0.5-meter diameter, film-cooled, high work aircraft turbine stages at rigorously simulated engine conditions has been designed, constructed, and tested. The simulation capability of the facility extends up to 40 atm inlet pressure at 2500°K (4000°F) turbine inlet temperatures. The facility is intended primarily for the exploration of unsteady, three-dimensional fluid mechanics and heat transfer in modern turbine stages.