The MIT Blowdown Turbine Facility

Alan H. Epstein, G. R. Guenette, R. J. G. Norton

1984 · 25 citations · 0 references

Concepts

Abstract

A short duration (0.4 sec) test facility, capable of testing 0.5-meter diameter, film-cooled, high work aircraft turbine stages at rigorously simulated engine conditions has been designed, constructed, and tested. The simulation capability of the facility extends up to 40 atm inlet pressure at 2500°K (4000°F) turbine inlet temperatures. The facility is intended primarily for the exploration of unsteady, three-dimensional fluid mechanics and heat transfer in modern turbine stages.