Medical Care · 1987 · 22 citations · 15 references
Health ProfessionsHealth Care ManagementHealth AssessmentHealth Care Quality ManagementHealthcare Quality ImprovementAdverse Event ReportingHealth Care QualityHealthcare Performance MeasurementQuality MeasurementQuality Of CareSeverity Of Illness DocumentationInterrater AgreementMedical Record AbstractionMedical Record AccuracyQuality Of Care AssessmentQuality Of Care MetricsSeverity Index MeasurementSeverity Of Illness ClassificationSeverity Rating Systems
Seven hundred fifty-two randomly selected charts from seven teaching hospitals were rated by pairs of medical record analysts. The Severity of Illness Index was unreliable with an interrater-agreement rate of 73% (kappa statistic = 0.41), and demonstrated a significant (P less than 0.0001) association with the Adverse Patient Occurrence (APO) Index. This suggests that the Severity of Illness Index is not differentiating severity of illness from quality of care. The fair to poor field reliability stems from underlying instrument subjectivity, lack of clear referent groups, and time pressure. The APO Index was also found to be unreliable (r = 0.33 and range = -0.05-0.58). Greater attention should be directed to improving objective discharge abstract, billing, and laboratory data for measuring patient severity and adverse patient occurrences.
15
Issues in the Use of Kappa to Estimate Reliability
Karen L. Soeken, Patricia A. Prescott · Medical Care · 1986 · 105 citations