Journal of Performance of Constructed Facilities · 1989 · 13 citations · 3 references
EngineeringBuilding ScienceCivil EngineeringBuilding StructuresStructural AnalysisStructural EngineeringBuilding ConstructionRetrofitting Existing BuildingsStructural Condition AssessmentStructural DesignStructural LoadsStructural SystemsAlternative Load PathsCollapse MechanismsLoad PathsPrecast ConcretePrecast Concrete ConstructionProgressive CollapseRetrofitStructural Vulnerability Assessment
AS part of a structural assessment of the new U.S. Embassy Office Building being constructed in Moscow, United Soviety Socialist Republic, the National Bureau of Standards determined the susceptibility of the building to progressive collapse, which might be triggered by a local failure of a primary load supporting structural member. The building is a precast concrete structure that uses a standardized Soviet building system. The paper discusses criteria for the progressive collapse analysis, mechanisms for alternative load paths, analysis techniques used, and recommended retrofit measures. Although the building system was not designed to provide continuity in structural connections, it is possible to protect the building against progressive collapse with relatively modest retrofit measures.
3
Minimum Design Loads for Buildings and Other Structures
Edward Cohen · 1990 · 1.4K citations
Building Code Requirements for Reinforced Concrete
ACI Committee · ACI Journal Proceedings · 1962 · 609 citations