IEEE Transactions on Industrial Electronics · 2013 · 50 citations · 24 references
EngineeringElectrical EngineeringEnergy ManagementEnergy SystemsPower ElectronicsAc-dc ConvertersConverter TopologiesPower Factor CorrectionPower QualityPower SystemsVoltage RegulationBoost ConvertersBoost Power Factor Correction ConvertersCore LossesDiscontinuous Conduction Mode OperationHarmonic DistortionLight-load EfficiencyLight-load OperationTotal Harmonic Distortion
This paper proposes an on/off control of boost power factor correction (PFC) converters to improve the light-load efficiency in paralleled power supply units (PSUs) for servers. The proposed scheme operates the PFC stages of two paralleled PSUs alternately during one cycle of a 60-Hz ac input only at light loads. This improves the light-load efficiency without deteriorating the heavy-load efficiency by reducing load-independent losses such as capacitive turn-on and core losses. In addition, the proposed scheme alleviates the harmonic distortion by reducing the discontinuous conduction mode region. Experimental results from 1.6-kW PFC boost converters are shown to verify the proposed work.
24
Single phase power factor correction: a survey
O. García, J.A. Cobos, R. Prieto et al. · IEEE Transactions on Power Electronics · 2003 · 658 citations
A classification and evaluation of paralleling methods for power supply modules
Shiguo Luo, Zhihong Ye, Ray‐Lee Lin et al. · 2003 · 389 citations