Journal of The Electrochemical Society · 1981 · 62 citations · 0 references
PharmacyElectrical EngineeringElectroanalytical MethodsElectrochemical EngineeringElectrochemistryElectrochemical DetectionElectrochemical Impedance SpectroscopyElectrochemical SensorsElectrode PotentialsNoiseWorking ElectrodesCurrent NoiseElectrochemical NoiseElectrochemical Noise AnalysisElectrode Potential MeasurementNoise CharacterizationNoise In AmplifiersNoise Power Spectral DensityPower Spectral Density
It is shown that by calculating the cross‐power spectrum between the input (the electrode potential) and the output (the cell current) of an electrochemical system under potentiostatic conditions, it is possible to identify which part of the cell current is the response to the input voltage and which part is caused by random fluctuations of the parameters characterizing the electrode. The noise introduced by the amplifiers can be measured separately and then subtracted from the signal. As an example, the current noise of an aluminum electrode below and at the pitting potential is examined. Both electrode impedance and spectral power density of the random fluctuations are obtained. It is shown that below the pitting potential random fluctuations are below the minimum detectable value of 10−23 A2/cm4 Hz.