Journal of Medical Physics · 2013 · 25 citations · 19 references
MedicineOncologyRadiation OncologyGynecologic Radiation OncologyRadiation DosimetryTreatment PlanningAbsorbed DoseGynecologic Cancer RadiotherapyIntensity-modulated RadiotherapyRadiation Dose MeasurementRadiation TherapyRadiation Treatment PlanningHomogeneity IndexPlan Quality MetricsRadiotherapy Plan EvaluationSpatial HomogeneityTreatment Plan EvaluationTreatment Plan OptimizationTreatment Planning OptimizationTreatment Planning System Validation
The aim of present study was to evaluate the intensity-modulated radiation therapy (IMRT) plans using different homogeneity and conformity indices in gynecological cancers, as well as to compare and find out the most reliable and accurate measure of the dose homogeneity among the available indices. In this study, a cohort of 12 patients were registered for evaluation, those receiving dynamic IMRT treatment on Clinac-2300C/D linear accelerator with 15-Mega Voltage (MV) photon beam. Dynamic IMRT plans were created on Eclipse treatment planning system with Helios dose volume optimization software. Homogeneity indices (HI) such as H index, modified H index, HI index, modified HI index, and S-index (sigma-index) proposed by M Yoon et al. (2007) were calculated and compared. The values of S-index vary from 1.63 to 2.99. The results indicate that the H and HI indices and their modified versions may not provide the correct dose homogeneity information, but the S-index provides accurate information about the dose homogeneity in the Planning Target Volume (PTV). Each plan was compared with 6-MV photon energy on the basis of S-index and conformity index (CI). Organs at risk (OAR) doses with 6-MV and 15-MV beams were also reported.
19
Michael Kam, Ricky Ming-chun Chau, Joyce Suen et al. · International Journal of Radiation Oncology*Biology*Physics · 2003 · 315 citations