Testing of Gloves for Permeability to UV-Curable Acrylate Coatings

R. A. Huggins, Nicole Levy, P.M. Pruitt

American Industrial Hygiene Association Journal · 1987 · 12 citations · 0 references

Concepts

Abstract

The handling of UV-curable acrylate formulations used in the coating of optical fiber requires protective measures to prevent contact dermatitis and/or allergic dermatitis. To characterize the permeability of various glove materials to a UV-curable acrylate coating, a study was undertaken using a modification of a standard ASTM permeability test, which demonstrated that nitrile rubber gloves provided the best protection of those glove materials tested.