Publication | Open Access
Reduced Testing Frequency for Glycated Hemoglobin, HbA1c, Is Associated With Deteriorating Diabetes Control
72
Citations
12
References
2014
Year
These findings provide, in a large, multicenter data set, objective evidence that testing outside guidance on HbA1c monitoring frequency is associated with a significant detrimental effect on diabetes control. To achieve the optimum downward trajectory in HbA1c, monitoring frequency should be quarterly, particularly in cases with suboptimal HbA1c. While this impact appears small, optimizing monitoring frequency across the diabetes population may have major implications for diabetes control and comorbidity risk.